Order of magnitude of renewable systems
By Bruno De Wachter / Published on Mon, 2006-12-18 08:30Typical values and world records
What are the typical electrical power output values of various renewable energy installations? The Institution of Engineering and Technology (IET) published a table of these values in their paper Environmental Effects of Electricity Generation (see paper page 49 table 11). The given values apply in the context of the UK. For your interest we added some world records to this table:
| Typical peak electrical power output for the UK (MW) | World record (MW) |
Solar (PV array)
| 0,01 to 0,09 | - |
Solar (power station)
| up to 1 | 10 (Pocking, Germany) |
Wave power
| 0.18 | 2,25 (Póvoa de Varzim, Portugal) |
Wind (single grid-connected turbine)
| up to 3 | 5 (Burnsbüttel, Germany) |
| Wind farm
| 10 | 735 (Horse Hollow, USA) |
| Generator fuelled by landfill gas
| up to 5 | 23 (Bandeirantes, Brazil) |
| Hydro (small scale)
| up to 5 | - |
| Hydro (large scale)
| 130 | 13320 (Itaipú, Brazil) |
| Geothermal
| 30 | 1000 (The Geysers, USA) |
| Burning of dry biomass materials
| 10 to 50 | 240 (Pietersaari, Finland) |
| Tidal barrage
| 240 | 240 (La Rance, France) |
Tagged with
Rating
People who read this also read
Popular content
- - Report - Renewables Support Schemes and Grid Integration Policies
- - Huge potential for energy savings: improved regulatory models for efficient investment and loss reduction in electricity network
- - Harmonics Impact Over Protection System of Power Generator
- - RETScreen Wins REEEP Funding for new MTV Tool
- - Energy master plan by OMA: North Sea super ring of wind farms
- - Report - Renewables Support Schemes and Grid Integration Policies
- - Chile – Renewable energy target attracts developers… even though there isn’t a green tariff
- - Research Priorities for Renewable Energy Technology by 2020 and Beyond
- - The cost development of wind energy
- - Are Zero Energy Buildings a Bridge too Far?