Monitoring Power Quality beyond EN 50160 and IEC 61000-4-30
By Hans De Keulenaer / Published on Fri, 2008-05-23 15:59By A Broshi
Power Quality monitoring has become a standard task in electrical network management.
The standards currently in place provide minimum requirements, since they want to create a level playing field that allows analyzers from different manufacturers to give the same results. It is good idea in concept, but it also acts as double edged sword. Manufacturers design their product to comply with these standards but typically do not provide data and measurements that would allow power quality analysis to go beyond current capabilities. To follow the guidelines set out by various standards and record faults or disturbances, today’s meters rely solely on event-based triggers. While this method provides engineers with some information regarding an event, it does not allow for full analysis of all power parameters leading up to an event, during an event or how the overall network recovers after an event. Further, due to limitations in memory storage, it is likely that even the data captured by such recording method(s) will not capture all of the ‘true’ power and energy parameters. In a majority of cases, these limitations prevent power quality phenomena from being truly solved and prevent solutions that will eliminate future recurrence.
This paper will highlight genuine case studies of Power Quality troubleshooting that was not capable of solving the Power Quality problem with measurements simply taken to comply with standards. It will further show that by providing engineers with data beyond the standards, an unprecedented number of Power Quality events can not only be captured, but are definitively solved.
Tagged with
Related content
- - Methods for power quality analysis according to EN 50160
- - Application Note - Standard EN 50160: Voltage Characteristics in Public Distribution Systems
- - IEC 61850 as a flexible tool for electrical systems Monitoring
- - Connection rules for possibly disturbing loads in Low Voltage Networks (IEC 61000 – 3 –11)
- - Connection rules for possibly disturbing loads in Low Voltage Networks (IEC 61000 – 3 – 12)
People who read this also read
Popular content
- - Report - Renewables Support Schemes and Grid Integration Policies
- - Huge potential for energy savings: improved regulatory models for efficient investment and loss reduction in electricity network
- - Harmonics Impact Over Protection System of Power Generator
- - RETScreen Wins REEEP Funding for new MTV Tool
- - Energy master plan by OMA: North Sea super ring of wind farms
- - Report - Renewables Support Schemes and Grid Integration Policies
- - Chile – Renewable energy target attracts developers… even though there isn’t a green tariff
- - Research Priorities for Renewable Energy Technology by 2020 and Beyond
- - The cost development of wind energy
- - Are Zero Energy Buildings a Bridge too Far?